Mars 70801 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Termostaty Mars 70801. Mars 70801 Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
INSTALLATION AND OPERATING INSTRUCTIONS
Non-Programmable Electronic
Thermostat Heat/Cool
®
Model 70801
70801-IM 12/14/06 3:06 PM Page 1
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Model 70801

INSTALLATION AND OPERATING INSTRUCTIONSNon-Programmable ElectronicThermostat Heat/Cool®Model 7080170801-IM 12/14/06 3:06 PM Page 1

Strona 2

10Wiring DiagramsTypical 2-Wire Millivolt SystemRC RHCGYWBOHEATCONTROL24 VACTRANSFORMERCOMHOTTypical Single Stage Heat Pump SystemRC RHCGYWBOFANCONTRO

Strona 3 - Installing The New Thermostat

11WarrantyONE YEAR LIMITED WARRANTYMotors & Armatures Inc. warrants each new MARS thermostat against any defects due tonon-conforming material or

Strona 4 - Testing The New Thermostat

INSTALLATION AND OPERATING INSTRUCTIONSNon-Programmable Electronic Thermostat Heat/Cool®Model 7080170801-IM 12/14/06 3:06 PM Page 12

Strona 5 - Programming The User Settings

2Compatible with low voltage single stage gas, oil or electric heating or cooling systems and single stageheat pumps. For use on 24VAC systems (not t

Strona 6 - Operating The New Thermostat

3Removing The Existing Thermostat1) CAUTION: Make certain the power to the system has been disconnected. 2) Remove the cover of the old thermostat a

Strona 7 - Troubleshooting

4• GAS / ELECTRIC: Configures the thermostat to either gas/oil or electric heating systems.• C / F: Sets the display in either Celsius or Fahrenheit.•

Strona 8

55) Set the system switch to the OFF position. The system shouldshut down within several seconds. The LCD will again displayonly the room temperatur

Strona 9

6Operating The New Thermostat1) Set the System switch to either the HEAT or COOL position and the Fan switch to either the AUTO or ONposition. NOTE:

Strona 10 - Wiring Diagrams

7TroubleshootingSYMPTOM CORRECTIVE ACTIONDisplay is blank Check thermostat wiring & connections.Check circuit breaker/fuse panel.No heat Set syste

Strona 11 - Warranty

8Wiring DiagramsTypical 4-Wire SystemRC RHCGYWBOFANCONTROLHEATCONTROLInstall Jumper24 VACTRANSFORMERCOOLCONTROLCOMHOT70801-IM 12/14/06 3:06 PM Page

Strona 12

9Wiring DiagramsTypical 5-Wire SystemRC RHCGYWBOFANCONTROLHEATCONTROLCOOLCONTROLHEAT 24 VACTRANSFORMERCOMHOTCOOL 24 VACTRANSFORMERCOMHOT70801-IM 12/1